Industry news

Structural characteristics and principles of electric ventilation butterfly valves

Butterfly valve is a type of regulating valve with a simple structure, and can also be used for on-off control of low-pressure pipeline media. The electric ventilation butterfly valve is a non closed type butterfly valve. Electric pneumatic ventilation butterfly valves are used in ventilation and environmental protection engineering in industries such as chemical, building materials, power plants, glass, etc., as pipeline control devices for regulating flow or cutting off gas medium in dusty cold or hot air gas pipelines. This ventilation valve should generally be installed horizontally in the pipeline.

Structural characteristics of electric ventilation butterfly valves

1. The new structural form designed and manufactured by welding the centerline plate and short structural steel plate features compact structure, light weight, easy installation, low flow resistance, large flow capacity, and easy operation.

2. No connecting rods, bolts, etc. inside, reliable operation, and long service life. It can be installed at multiple workstations without being affected by the flow direction of the medium.

The purpose of ventilation butterfly valve

Ventilation butterfly valve is a non closed type butterfly valve widely used in production processes such as building materials, metallurgy, mining, and power. It is used for connecting, opening, closing, or regulating medium flow in pipelines with a medium temperature ≤ 300 ℃ and a nominal pressure of 0.1Mpa.

Working principle of electric ventilation butterfly valve

The electric ventilation butterfly valve is driven by an electric motor to drive the actuator, allowing the butterfly plate to rotate freely within a 90 ° range to achieve the purpose of opening and closing or regulating medium flow. Electric actuators are generally 220V or 380V, switch type and adjustable type.

Key points of ventilation butterfly valve installation

1. The position, height, and inlet and outlet directions of the device must meet the design requirements. It is important to note that the direction of medium flow should be consistent with the arrow direction marked on the valve body, and the connection should be firm and tight.

2. Before installing the valve, it is necessary to conduct a visual inspection, and the nameplate of the valve should comply with the current national standard "General Valve Markings" GB12220. Strength and tightness tests should be conducted before the device is installed, and it can only be used after passing the tests. During the strength test, the test pressure shall be 1.5 times the nominal pressure, and the valve shell and packing shall be deemed qualified if there is no leakage for no less than 5 minutes. During the tightness test, the test pressure shall be 1.1 times the nominal pressure; The duration of the test shall comply with the requirements of GB50243.

PREVIOUS:Application principle of pneumatic ventilation disc valve

NEXT:What are the characteristics and applications of ventilation butterfly valves

Leave a Reply

0577-6733-1660

angelinge1212

8615888749866

yoyo@vitalvalves.com

1227498965

Leave a message